CDE Detailed Report
Disease: cookie-policy
Sub-Domain: Assessments and Examinations
CRF:

Displaying 1 - 50 of 76
CDE ID CDE Name Variable Name Definition Short Description Additional Notes (Question Text) Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guideline) Sub Domain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type Source Form Set Form Field Domain CDASH Variable CDASH Definition CDASH Label Controlled Terminology Prompt Essentiality Question Text CDASH imp guidance SDTM IG target csDSR PhenX Data Type CRF Completion Inst SDTMIG Target Var SDTMIG Target Map Codelist Name PVs Pre Pop Value Query Display List Style
C14003 Imaging brain death present indicator ImgBrainDeathPresInd Indicates presence of brain death Indicates presence of brain death Brain Death Yes;No;Unknown Yes;No;Unknown Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14036 Breath-holding index result BreathHoldingIndexReslt Indicates breath-holding index (BHI) result Indicates breath-holding index (BHI) result Breath-holding index (BHI) Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics 255

Free-Form Entry

C13751 Imaging acquisition reason ImgAcquisitionRsn Describes why the imaging study was performed Describes why the imaging study was performed Scan purpose Diagnostic;Post-treatment;Monitoring;Other, specify;Diagnostic;Post-treatment;Monitoring;Other, specify Diagnostic;Post-treatment;Monitoring;Other, specify;Diagnostic;Post-treatment;Monitoring;Other, specify Alphanumeric

Select all that apply

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Multiple Pre-Defined Values Selected

C14014 Intracranial stenosis other criteria result IntracranStenoOthCriteriaReslt Other criteria for intracranial stenosis Other criteria for intracranial stenosis Other Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics 255

Free-Form Entry

C18901 Sickle cell disease vessel anatomic other text SickleCellDisVesselAntmicOTH The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel Other, specify Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics 4000

Free-Form Entry

C13949 Imaging flow/probe direction type ImgFlowProbDireTyp Indicates flow/probe direction Indicates flow/probe direction Direction of Probe Towards;Away from Towards;Away from Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)
Highly recommended for Stroke imaging studies

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14026 Intracranial pressure imaging result ICPReslt Indicates intracranial pressure (ICP) imaging result Indicates vasospasm intracranial pressure (ICP) imaging result Intracranial pressure Numeric Values

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

0 999 millimeter of mercury
C14004 Imaging brain death vessel anatomic site ImgBrainDeathVesseIAntmicSite Indicates brain death vessel(s) Indicates brain death vessel(s) Vessel(s) ICA;Basilar;MCA;Other, specify;ACA;VA;PCA;Ophthalmic artery Internal carotid artery;Basilar;Middle cerebral artery;Other, specify;Anterior carotid artery;Vertebral artery;Posterior carotid artery;Ophthalmic artery Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Multiple Pre-Defined Values Selected

C14037 Imaging power M mode left middle cerebral artery result ImgPowerMModeLeftMCARes Indicates power M mode for left middle cerebral artery (MCA) result Indicates power M mode for left middle cerebral artery (MCA) result Left MCA Absent;High Resistance;Low Resistance;Absent;High Resistance;Low Resistance Absent;High Resistance;Low Resistance;Absent;High Resistance;Low Resistance Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C13899 Imaging probe type text ImgProbeTypTxt The text describing the type of imaging probe Describes imaging probe type Type Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics 255

Free-Form Entry

C14015 Microembolic signal count MicroembolSignalCt Numeric value counting the number of microembolic signals. Indicates microembolic signal number Number Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

0 999
C18902 Vasospasm vessel anatomic other text VasospasmVesselAntmicOTH The free-text field related to 'Vasospasm vessel anatomic site' specifying other text. Indicates vasospasm vessel(s) The free-text field related to 'Vasospasm vessel anatomic site' specifying other text. Indicates vasospasm vessel(s) Other, specify Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics 4000

Free-Form Entry

C13956 Microembolic signal duration MicroembolSignalDur Indicates microembolic signal duration time (msec) Indicates microembolic signal duration time (msec) Duration time Numeric Values

Indicate duration time in units of msec

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

0 999 millisecond
C14027 Intracranial pressure (ICP) other measurement text ICPOtherMeasrTxt Indicates other method of measuring intracranial pressure (ICP) Indicates other method of measuring intracranial pressure (ICP) Other Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics 255

Free-Form Entry

C14005 Imaging brain death diagnosis result ImgBrainDeathDiagReslt Indicates brain death diagnosis result Indicates brain death diagnosis result Brain Death Reversed Diastolic Flow;Systolic spike;No signals Reversed Diastolic Flow;Systolic spike;No signals Alphanumeric

Select all that apply

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Multiple Pre-Defined Values Selected

C14038 Imaging power M mode right middle cerebral artery result ImgPowerMModeRightMCARes Indicates power M mode for right middle cerebral artery (MCA) result Indicates power M mode for right middle cerebral artery (MCA) result Right MCA Absent;High Resistance;Low Resistance;Absent;High Resistance;Low Resistance Absent;High Resistance;Low Resistance;Absent;High Resistance;Low Resistance Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C01559 Arterial partial pressure carbon dioxide value ArterialPPCO2Val Measurement of how much carbon dioxide is dissolved in the arterial blood and how well carbon dioxide is able to move out of the body (PaCO2) Measurement of how much carbon dioxide is dissolved in the arterial blood and how well carbon dioxide is able to move out of the body (PaCO2) Partial pressure of carbon dioxide (PCO2) Numeric Values

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-07-20 10:21:25.65 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

0 100 millimeter of mercury
C13900 Imaging probe frequency ImgProbeFreq Indicates imaging probe frequency (Hz) Indicates imaging probe frequency (Hz) Frequency Numeric Values

Indicate frequency in units of Hz

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

Hertz
C14016 Microembolic signal start time MicroembolSignalStartTime Indicates microembolic signal start time Indicates microembolic signal start time Start Time Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

C18903 Vasomotor response (VMR) vessel anatomic other text VMRVesselAntmicOTH The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type Other, specify Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics 4000

Free-Form Entry

C13957 Microembolic signal intensity value MicroembolSignalIntensVal Indicates microembolic signal intensity value (dB) Indicates microembolic signal intensity value (dB) Intensity Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

decibel
C14028 Vasospasm present indicator VasoPresInd Indicates presence of vasospasm Indicates presence of vasospasm Vasospasm Yes;No;Unknown Yes;No;Unknown Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14006 Imaging stenosis percentage value ImgStenosisPercentageVal Indicates stenosis percentage value Indicates stenosis percentage value Percent Stenosis Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

0 99 percent
C14051 Microembolic signal end time MicroembolSignalEndTime Indicates microembolic signal end time Indicates microembolic signal end time End Time Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

C02411 Laterality type LatTyp Laterality type relative to the anatomic site of the body examined or affected Laterality type relative to the anatomic site of the body examined or affected Specify laterality Alphanumeric

No instructions available
Highly recommended for Stroke imaging studies

No references available Adult;Pediatric Proposed 3.00 2013-08-28 16:08:00.453 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C13901 Imaging patient type ImgPatientTyp Indicates imaging patient type Indicates imaging patient type Patient type Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14017 Microembolic signal unidirectional indicator MicroembolSignalUnidirectInd Indicates unidirectional microembolic signal Indicates unidirectional microembolic signal Unidirectional Yes;No;Unknown Yes;No;Unknown Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C13958 Microembolic signal settings type MicroembolSignalSettingTyp Indicates microembolic signal settings category Indicates microembolic signal settings category Settings Leading cols;Trailing cols;Threshold;Rejection Leading cols;Trailing cols;Threshold;Rejection Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14029 Vasospasm posterior ratio result VasoPosterRatioReslt Indicates vasospasm posterior ratio result Indicates vasospasm posterior ratio result Posterior ratio Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

0 10
C14007 Imaging Transcranial Doppler (TCD) findings result type ImgTCDFindResltTyp Indicates Transcranial Doppler (TCD) findings Indicates Transcranial Doppler (TCD) findings Findings Reversed Diastolic Flow;Systolic spike;No signals;Reduced upstroke/Pulsatility Index (PI) Reversed Diastolic Flow;Systolic spike;No signals;Reduced upstroke/Pulsatility Index (PI) Alphanumeric

Select all that apply
Highly recommended for Stroke imaging studies

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Multiple Pre-Defined Values Selected

DeBaun Forms
C14052 Hemoglobin measurement HemoglobMeasr The measurement for hemoglobin. The measurement for hemoglobin. Hemoglobin Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

g/dL DeBaun Forms
C02494 Imaging study date and time ImgStdyDateTime Date (and time, if applicable and known) the radiologic study was obtained. Date (and time, if applicable and known) the radiologic study was obtained. Date and time of study Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).
Highly recommended for Stroke imaging studies

Duhaime AC, Gean AD, Haacke EM, Hicks R, Wintermark M, Mukherjee P, Brody D, Latour L, Riedy G; Common Data Elements Neuroimaging Working Group Members, Pediatric Working Group Members. Common data elements in radiologic imaging of traumatic brain injury. Arch Phys Med Rehabil. 2010 Nov;91(11):1661-6. [DOI: 10.1016/j.apmr.2010.07.238] Adult;Pediatric Proposed 3.00 2013-08-28 16:08:00.453 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

C13902 Imaging acute stroke study type ImgAcutStokStudTyp Indicates imaging acute stroke study type Indicates imaging acute stroke study type Indicate study type Initial;Follow-up 1;Follow-up 2 Initial;Follow-up 1;Follow-up 2 Alphanumeric

Contains data elements collected when an imaging study is performed using carotid ultrasound to examine the two large arteries in the neck; there are separate sections to record findings from B-mode and color flow imaging. (Examples of CDEs included: Severity of plaque; Percent stenosis; and Mean lumen diameter)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14019 Sickle cell disease present indicator SickleCellPresInd Indicates presence of sickle cell Indicates presence of sickle cell Sickle Cell Yes;No;Unknown Yes;No;Unknown Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

DeBaun Forms
C13959 Microembolic signal measurement MicroembolSignalMeasr Indicates actual settings measurement for all categories (mm) Indicates actual settings measurement for all categories (mm) Settings Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

millimeter
C14030 Vasospasm resistive index indicator VasospasmRestistIndexInd Indicates vasospasm resistive Index (RI) Indicates vasospasm resistive Index (RI) Resistive index Yes;No;Unknown Yes;No;Unknown Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C08254 Imaging visual analysis location performed type ImgVisAnlysisLocPerfTyp Location where visual analysis of the imaging data are performed Location where visual analysis of the imaging data are performed Read type Central;Central read;Local - Site;Local read;Local report;Other, specify Central;Central read;Local - Site;Local read;Local report;Other, specify Alphanumeric

Select all that apply

No references available Adult;Pediatric Proposed 3.00 2013-07-25 08:54:08.2 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14008 Imaging window quality category ImgWindowQualityCat Indicates window quality category Indicates window quality category Insonation plane: Temporal;Posterior;Orbital Temporal;Posterior;Orbital Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14056 Imaging depth measurement ImgDepthMeasr The depth measurement (mm) of imaging. The depth measurement (mm) of imaging. Depth Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)
Highly recommended for Stroke imaging studies

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

0 999 millimeter
C13903 Imaging interpretation site indicator ImgInterpretSiteInd Indicates imaging interpretation site Indicates imaging interpretation site Interpretation site Onsite;Offsite Onsite;Offsite Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14020 Sickle cell disease vessel anatomic site SickleCellDisVesselAntmicSite Indicates sickle cell vessel Indicates sickle cell vessel Vessel(s) ICA;MCA;ACA;Other, specify Internal carotid artery;Middle cerebral artery;Anterior carotid artery;Other, specify Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Multiple Pre-Defined Values Selected

C13960 Microembolic signal vessel anatomic site MicroembolSignVesselAntmicSite Indicates microembolic signal vessel category Indicates microembolic signal vessel category Microembolic signals M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Multiple Pre-Defined Values Selected

C14031 Vasospasm status VasospasmStatus Indicates vasospasm result Indicates vasospasm result Vasospasm Abnormal;Normal;Abnormal;Normal Abnormal;Normal;Abnormal;Normal Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C08255 Imaging visual analysis blinded indicator ImgVisAnlysisBlindInd Indicator of whether the visual analysis was performed blinded to clinical data Indicator of whether the visual analysis was performed blinded to clinical data Reader blinded to clinical data Yes;No;Unknown Yes;No;Unknown Alphanumeric

Contains data elements collected when an imaging study is performed using angiography to examine the blood vessels of the body; there are separate sections to record arterial findings and venous findings. (Examples of CDEs included: Findings for each artery; TIMI scale individual vessel score; and Collateral grade)

No references available Adult;Pediatric Proposed 3.00 2013-07-25 08:54:08.2 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14009 Imaging window quality result ImgWindowQualityReslt Indicates window quality result for all categories Indicates window quality result for all categories Window quality Fair;Excellent;Poor;Fair;Excellent;Poor Fair;Excellent;Poor;Fair;Excellent;Poor Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C18693 Imaging contrast agent method other text ImgContrastAgentMethodOTH The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration Other, specify Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 1.00 2014-05-27 13:34:46.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics 4000

Free-Form Entry

C13904 Imaging interpretation offsite media type ImgInterpretOffsiteMediaTyp Indicates imaging offsite media type Indicates imaging offsite media type Indicate type Video;Print;Digital Video;Print;Digital Alphanumeric

Contains data elements collected when an imaging study is performed using carotid ultrasound to examine the two large arteries in the neck; there are separate sections to record findings from B-mode and color flow imaging. (Examples of CDEs included: Severity of plaque; Percent stenosis; and Mean lumen diameter)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14021 Sickle cell disease velocity measurement SickleCellVelMeasr The velocity measurement of sickle cell. The velocity measurement of sickle cell. Velocity Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Free-Form Entry

0 999 centimeter per second DeBaun Forms
C13961 Microembolic signals present indicator MicroembolSignalPresentInd Indicates presence of microembolic signals Indicates presence of microembolic signals Microembolic signals Yes;No;Unknown Yes;No;Unknown Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

C14032 Vasospasm severity grade VasospasmSeverGrade Indicates severity of vasospasm Indicates severity of vasospasm Severity Mild;Moderate;Severe Mild;Moderate;Severe Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Proposed 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Doppler (TCD) Assessments and Examinations Imaging Diagnostics

Single Pre-Defined Value Selected

Displaying 1 - 50 of 76
CSV