CDE Detailed Report
Disease: cookie-policy
Sub-Domain: Additional Proposed Instruments
CRF:

Displaying 201 - 250 of 378
CDE ID CDE Name Variable Name Definition Short Description Additional Notes (Question Text) Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guideline) Sub Domain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type Source Form Set Form Field Domain CDASH Variable CDASH Definition CDASH Label Controlled Terminology Prompt Essentiality Question Text CDASH imp guidance SDTM IG target csDSR PhenX Data Type CRF Completion Inst SDTMIG Target Var SDTMIG Target Map Codelist Name PVs Pre Pop Value Query Display List Style
C13938 Imaging minimum lumen diameter measurement ImgMinLumenDiameterMeasr Indicates minimum lumen diameter measurement (mm) Indicates minimum lumen diameter measurement (mm) Numeric Values Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

millimeter
C54612 Brief Test of Executive Function Second Edition (BRIEF 2) - Working memory total raw scale score BRIEF2WrkngMmryTtlRwSclScore Total score of the raw scale for the working memory function, as part of the Brief Test of Executive Function Second Edition (BRIEF 2) Total score of the raw scale for the working memory function, as part of the Brief Test of Executive Function Second Edition (BRIEF 2) Numeric Values Adult;Pediatric Supplemental 1.00 2017-03-22 09:57:02.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C56431 Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) - Perceptual Reasoning confidence interval lower bound value WASIIIPercRsngConfIntrvlLowVal The lower bound of the subject's Perceptual Reasoning confidence interval, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). The lower bound of the subject's Perceptual Reasoning confidence interval, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-12 12:55:22.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C13949 Imaging flow/probe direction type ImgFlowProbDireTyp Indicates flow/probe direction Indicates flow/probe direction Towards;Away from Towards;Away from Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C18719 Imaging slice orientation other text ImgSliceOrientOTH The free-text field related to 'Imaging slice orientation type' specifying other text. The slice orientation used in imaging acquisition The free-text field related to 'Imaging slice orientation type' specifying other text. The slice orientation used in imaging acquisition Alphanumeric Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 PhenX CDEs Additional Proposed Instruments Phen-X 4000

Free-Form Entry

C13884 Imaging vessel angiography arterial anatomic site ImgVesselAngioArterAntmicSite Indicates vessel imaging angiography arterial findings location Indicates vessel imaging angiography arterial findings location CCA origin;CCA to bifurcation;ICA at origin;C1 cervical;C2 petrous;C3 lacerum;C4 cavernous;C5 clinoidal;C6 - ophthalmic to PCOM;C6 - PCOM to terminus;A1;A2;M1 proximal to striate;M1 distal to striate;M2 single;M2 multiple;M3 single;M3 multiple;M4 single;M4 multiple;Vertebral origin;Vertebral- cervical;Vertebral-intracranial proximal to PICA;Vertebral-distal to PICA;Basilar-distal to AICA;Basilar-mid;Basilar-proximal to AICA;PCOM;P1;P2;P3;SCA;AICA;PICA;CCA origin;CCA to bifurcation;ICA at origin;C1 cervical;C2 petrous;C3 lacerum;C4 cavernous;C5 clinoidal;C6 - ophthalmic to PCOM;C6 - PCOM to terminus;A1;A2;M1 proximal to striate;M1 distal to striate;M2 single;M2 multiple;M3 single;M3 multiple;M4 single;M4 multiple;Vertebral origin;Vertebral- cervical;Vertebral-intracranial proximal to PICA;Vertebral-distal to PICA;Basilar-distal to AICA;Basilar-mid;Basilar-proximal to AICA;PCOM;P1;P2;P3;SCA;AICA;PICA Common carotid artery origin;Common carotid artery to bifurcation;Internal carotid artery at origin;C1 cervical;C2 petrous;C3 lacerum;C4 cavernous;C5 clinoidal;C6 - ophthalmic to PCOM;C6 - PCOM to terminus;A1;A2;M1 proximal to striate;M1 distal to striate;M2 single;M2 multiple;M3 single;M3 multiple;M4 single;M4 multiple;Vertebral origin;Vertebral- cervical;Vertebral-intracranial proximal to PICA;Vertebral-distal to PICA;Basilar-distal to AICA;Basilar-mid;Basilar-proximal to AICA;PCOM;P1;P2;P3;SCA;AICA;PICA;Common carotid artery origin;Common carotid artery to bifurcation;Internal carotid artery at origin;C1 cervical;C2 petrous;C3 lacerum;C4 cavernous;C5 clinoidal;C6 - ophthalmic to PCOM;C6 - PCOM to terminus;A1;A2;M1 proximal to striate;M1 distal to striate;M2 single;M2 multiple;M3 single;M3 multiple;M4 single;M4 multiple;Vertebral origin;Vertebral- cervical;Vertebral-intracranial proximal to PICA;Vertebral-distal to PICA;Basilar-distal to AICA;Basilar-mid;Basilar-proximal to AICA;PCOM;P1;P2;P3;SCA;AICA;PICA Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C14008 Imaging window quality category ImgWindowQualityCat Indicates window quality category Indicates window quality category Temporal;Posterior;Orbital Temporal;Posterior;Orbital Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C10927 Imaging inversion time ImgInversionTime The time period between the 180° inversion pulse and the 90° excitation pulse in an Inversion Recovery pulse sequence. The time period between the 180° inversion pulse and the 90° excitation pulse in an Inversion Recovery pulse sequence. Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

millisecond
C21489 Wechsler Adult Intelligence Scale IV (WAIS IV) - Digit span forward subtest last trial correct digit score WAISIVLDSFScore Score for the digits reported correctly by the subject/participant during the last trial of the Digit Span Forward subtest, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Score for the digits reported correctly by the subject/participant during the last trial of the Digit Span Forward subtest, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Numeric Values Adult;Pediatric Supplemental 1.00 2015-07-22 11:32:44.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0 9
C56388 Conners Continuous Performance Test 3rd Edition (CPT3) - Impulsivity commission count ConnersCPT3ImpCommCt The number of incorrect responses to non-targets, as part of the Conners Continuous Performance Test 3rd Edition (CPT3). The number of incorrect responses to non-targets, as part of the Conners Continuous Performance Test 3rd Edition (CPT3). Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-09 15:38:27.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0
C13917 Imaging end diastolic velocity measurement ImgEndDiastVeloMears Indicates end diastolic velocity (cm/sec) Indicates end diastolic velocity (cm/sec) Numeric Values Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

centimeter per second
C14056 Imaging depth measurement ImgDepthMeasr The depth measurement (mm) of imaging. The depth measurement (mm) of imaging. Numeric Values Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0 999 millimeter
C12499 Imaging T2 weighted white matter abnormality site type ImgT2WWMAbnrmlySiteTyp The type of anatomical site of the white matter abnormality on T2 weighted images The type of anatomical site of the white matter abnormality on T2 weighted images Frontal;Parietal;Temporal;Cerebellar WM;Deep WM;Diffuse;Occipital;Periventricular Frontal;Parietal;Temporal;Cerebellar WM;Deep WM;Diffuse;Occipital;Periventricular Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 PhenX CDEs Additional Proposed Instruments Phen-X

Multiple Pre-Defined Values Selected

C13235 National Institutes of Health Stroke Scale (NIHSS) - Best gaze score NIHSSLvlConscBestGazeScore Best gaze assessed using the NIH Stroke Scale (NIHSS) Best gaze assessed using the NIH Stroke Scale (NIHSS) 0;1;2;0;1;2 Normal;Partial gaze palsy. This score is given when gaze is abnormal in one or both eyes, but where forced deviation or total gaze paresis are not present;Forced deviation, or total gaze paresis not overcome by the oculocephalic maneuver;Normal;Partial gaze palsy. This score is given when gaze is abnormal in one or both eyes, but where forced deviation or total gaze paresis are not present;Forced deviation, or total gaze paresis not overcome by the oculocephalic maneuver Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

DeBaun Forms
C54695 PROMIS - Global Health fatigue rate scale PROMISGlbHlthFtgRtScl Scale related to an individual's rating of his/her fatigue, as part of the PROMIS Global Health Scale related to an individual's rating of his/her fatigue, as part of the PROMIS Global Health 1;2;3;4;5;1;2;3;4;5 Excellent;Very good;Good;Fair;Poor;Excellent;Very good;Good;Fair;Poor Alphanumeric Adult;Pediatric Supplemental 1.00 2017-04-07 15:34:25.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C02494 Imaging study date and time ImgStdyDateTime Date (and time, if applicable and known) the radiologic study was obtained. Date (and time, if applicable and known) the radiologic study was obtained. Date or Date & Time Adult;Pediatric Supplemental 3.00 2013-08-28 16:08:00.453 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C18891 Imaging vessel angiography collateral status anatomic other text ImgVessAngioCollatStatAntOTH The free-text field related to 'Imaging vessel angiography collateral status anatomic site' specifying other text. Indicates vessel angiography collateral status location The free-text field related to 'Imaging vessel angiography collateral status anatomic site' specifying other text. Indicates vessel angiography collateral status location Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X 4000

Free-Form Entry

C13896 Imaging vessel angiography level of confidence status ImgVesselAngioLvlConfidTyp Indicates vessel angiography level of confidence Indicates vessel angiography level of confidence Low;Moderate;High Low;Moderate;High Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C14020 Sickle cell disease vessel anatomic site SickleCellDisVesselAntmicSite Indicates sickle cell vessel Indicates sickle cell vessel ICA;MCA;ACA;Other, specify Internal carotid artery;Middle cerebral artery;Anterior carotid artery;Other, specify Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Multiple Pre-Defined Values Selected

C12478 Imaging cortex-pachygyria indicator ImgCortexPachygyriaInd Indicator of whether cortex-pachygyria are found within the image studies Indicator of whether cortex-pachygyria are found within the image studies Yes;No;Unknown Yes;No;Unknown Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C21500 Wechsler Adult Intelligence Scale IV (WAIS IV) - Digit span sequencing subtest number series text WAISIVDSSNumTxt Series of numbers, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Sequencing subtest Series of numbers, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Sequencing subtest Numeric Values Adult;Pediatric Supplemental 1.00 2015-07-22 11:32:44.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0 50
C56409 Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) - Similarities raw score WASIIISimRawScore The raw score that the subject received on the Similarities subtest of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) . The raw score that the subject received on the Similarities subtest of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-12 11:23:35.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0 45
C13928 Intima media thickness (IMT) electronic caliper indicator IMTElectronicCaliperInd Indicates intima media thickness (IMT) electronic caliper use Indicates intima media thickness (IMT) electronic caliper use Yes;No;Unknown Yes;No;Unknown Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C15555 Imaging visual analysis performed indicator ImgVisAnlysisPerfrmInd Whether visual analysis was performed while blind to clinical data Whether visual analysis was performed while blind to clinical data Yes;No;Unknown Yes;No;Unknown Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C13939 Imaging mean interadventitial diameter measurement ImgMeanInteradventlDiamtMeasr Indicates mean interadventitial diameter measurement (mm) Indicates mean interadventitial diameter measurement (mm) Numeric Values Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

millimeter
C17931 Imaging magnetic resonance imaging performed indicator ImgMRIPerfInd Indicator as to whether or not Magnetic Resonance Imaging (MRI) on the brain has been performed on the participant/subject Indicator as to whether or not Magnetic Resonance Imaging (MRI) on the brain has been performed on the participant/subject Yes;No;Unknown Yes;No;Unknown Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C13246 National Institutes of Health Stroke Scale (NIHSS) Supplemental - Intervention present type NIHSSSupInterventPresentTyp Were any of the following present during the NIHSS assessment? Were any of the following present during the NIHSS assessment? Endotracheal intubation/tracheostomy;Pharmacological sedation;Pharmacological paralysis;Endotracheal intubation/tracheostomy;Pharmacological sedation;Pharmacological paralysis Endotracheal intubation/tracheostomy;Pharmacological sedation;Pharmacological paralysis;Endotracheal intubation/tracheostomy;Pharmacological sedation;Pharmacological paralysis Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Multiple Pre-Defined Values Selected

C13960 Microembolic signal vessel anatomic site MicroembolSignVesselAntmicSite Indicates microembolic signal vessel category Indicates microembolic signal vessel category M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Multiple Pre-Defined Values Selected

C08245 Imaging slice count ImgSliceCt Count representing the total number of single image planes captured during imaging acquisition Count representing the total number of single image planes captured during imaging acquisition Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C20417 National Institutes of Health Stroke Scale (NIHSS) - Motor leg amputation text NIHSSMotLegAmpTxt The text field for explaining the amputation or joint fusion for question related to motor ability of the leg (both left and right) assessed using the NIH Stroke Scale (NIHSS). The text field for explaining the amputation or joint fusion for question related to motor ability of the leg (both left and right) assessed using the NIH Stroke Scale (NIHSS). Alphanumeric Adult;Pediatric Supplemental 4.00 2015-04-27 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X 4000

Free-Form Entry

C55780 Imaging vessel studied text ImagVessStudTxt Text describing any and all of the subject's vessels that were studied. Text describing any and all of the subject's vessels that were studied. Alphanumeric Adult;Pediatric Supplemental 1.00 2017-05-31 12:30:51.0 PhenX CDEs Additional Proposed Instruments Phen-X 255

Free-Form Entry

C13907 Imaging B-mode finding result ImgBModFindReslt Indicates B-mode finding Indicates B-mode finding Normal;Plaque Normal;Plaque Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C14031 Vasospasm status VasospasmStatus Indicates vasospasm result Indicates vasospasm result Abnormal;Normal;Abnormal;Normal Abnormal;Normal;Abnormal;Normal Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C12489 Imaging subcortical cysts site type ImgSubCorticalCystSiteTyp The anatomical site(s) of the subcortical cysts The anatomical site(s) of the subcortical cysts Temporal;Frontoparietal;Occipital Temporal;Frontoparietal;Occipital Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X

Multiple Pre-Defined Values Selected

C54602 Behavior Rating Inventory of Executive Function 2nd Edition (BRIEF 2) - Form version name BRIEF2FormVersionName Name of the version of the form, as part of the Behavior Rating Inventory of Executive Function 2nd Edition (BRIEF 2) Name of the version of the form, as part of the Behavior Rating Inventory of Executive Function 2nd Edition (BRIEF 2) Parent form;Self form;Teacher form Parent form;Self form;Teacher form Alphanumeric Adult;Pediatric Supplemental 1.00 2017-03-20 15:13:56.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C56421 Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) - Examinee visual hearing aid prescription lens used indicator WASIIIExVisHeaAidPreLensUseInd The indicator relating to the examine used his/her prescription lenses during testing, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). The indicator relating to the examine used his/her prescription lenses during testing, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). Used;Not used Used;Not used Alphanumeric Adult;Pediatric Supplemental 1.00 2017-06-12 11:54:51.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C54613 Brief Test of Executive Function Second Edition (BRIEF 2) - Plan organize total raw scale score BRIEF2PlnOrgnzTtlRwSclScore Total score of the raw scale for the plan/organize function, as part of the Brief Test of Executive Function Second Edition (BRIEF 2) Total score of the raw scale for the plan/organize function, as part of the Brief Test of Executive Function Second Edition (BRIEF 2) Numeric Values Adult;Pediatric Supplemental 1.00 2017-03-22 09:57:02.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C56433 Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) - Perceptual Reasoning confidence interval upper bound value WASIIIPercRsngConfIntrvlUppVal The upper bound of the subject's Perceptual Reasoning confidence interval, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). The upper bound of the subject's Perceptual Reasoning confidence interval, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-12 12:55:22.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C13950 Imaging spectrum asymmetry index result ImgSpectrumAsymmetryIndexReslt Indicates spectrum asymmetry index result Indicates spectrum asymmetry index result Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X 255

Free-Form Entry

C18720 Imaging visual analysis location performed other text ImgVisAnlysisLocPerfOTH The free-text field related to 'Imaging visual analysis location performed type' specifying other text. Location where visual analysis of the imaging data are performed The free-text field related to 'Imaging visual analysis location performed type' specifying other text. Location where visual analysis of the imaging data are performed Alphanumeric Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 PhenX CDEs Additional Proposed Instruments Phen-X 4000

Free-Form Entry

C13885 Imaging vessel angiography arterial result ImgVesselAngioArterialReslt Indicates vessel imaging angiography arterial findings Indicates vessel imaging angiography arterial findings Normal;Occlusion;Aneurysm;Stenosis;AVM;Not visualized Normal;Occlusion;Aneurysm;Stenosis;AVM;Not visualized Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C14009 Imaging window quality result ImgWindowQualityReslt Indicates window quality result for all categories Indicates window quality result for all categories Fair;Excellent;Poor;Fair;Excellent;Poor Fair;Excellent;Poor;Fair;Excellent;Poor Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C10931 Imaging quality of images technically satisfactory indicator ImgQualImgTechnSatisInd Indicator of whether the quality of the images were technically satisfactory. Indicator of whether the quality of the images were technically satisfactory. Yes;No;Unknown;Not applicable Yes;No;Unknown;Not applicable Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C21490 Wechsler Adult Intelligence Scale IV (WAIS IV) - Digit span forward subtest total raw score WAISIVDSFTtlScore Total raw score, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Forward subtest Total raw score, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Forward subtest Numeric Values Adult;Pediatric Supplemental 1.00 2015-07-22 11:32:44.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0 16
C56390 Conners Continuous Performance Test 3rd Edition (CPT3) - Impulsivity perseveration count ConnersCPT3ImpPersCt The number of random or anticipatory responses, as part of the Conners Continuous Performance Test 3rd Edition (CPT3). The number of random or anticipatory responses, as part of the Conners Continuous Performance Test 3rd Edition (CPT3). Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-09 15:39:31.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0
C13918 Imaging no signal indicator ImgNoSignalInd Indicates no signal on the carotid ultrasound Indicates no signal on the carotid ultrasound Yes;No;Unknown Yes;No;Unknown Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C14678 Pediatric Migraine Disability Assessment (MIDAS) - headache school absence day count PedMIDASHeadSchAbseDayCt Count missed full school days in the last 3 months due to headaches, as part of migraine disability assessment (MIDAS) questionnaire-pediatric form. Count missed full school days in the last 3 months due to headaches, as part of migraine disability assessment (MIDAS) questionnaire-pediatric form. Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0 92
C12500 Imaging corpus callosum type indicator ImgCrpsClsmTypInd The condition of the corpus callosum fibers The condition of the corpus callosum fibers Involved;Spared Involved;Spared Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C13236 National Institutes of Health Stroke Scale (NIHSS) - Visual field score NIHSSLvlConscVisuFldScore Visual fields assessed using the NIH Stroke Scale (NIHSS) Visual fields assessed using the NIH Stroke Scale (NIHSS) 0;1;2;3;UN;0;1;2;3;UN No visual loss;Partial hemianopia;Complete hemianopia;Bilateral hemianopia (blind including cortical blindness);Unexaminable (intubated/paralyzed);No visual loss;Partial hemianopia;Complete hemianopia;Bilateral hemianopia (blind including cortical blindness);Unexaminable (intubated/paralyzed) Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

DeBaun Forms
C55773 Imaging MRI scanner used count ImagMRIScanUsedCt The number of different MRI scanners that were used on the subject. The number of different MRI scanners that were used on the subject. Numeric Values Adult;Pediatric Supplemental 1.00 2017-05-31 12:11:13.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

Displaying 201 - 250 of 378
CSV